Like icing on a cake transitions are typically the last materials to complete the floating floor project.
Mason fsn floating floor mount.
Mason jack up floor slab system we believe that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
Air gap a floor thickness b.
We believe that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
When installed correctly they can last for.
Fsn jack up floating floor isolation mounts it has been proven that the most fool proof and safest way to establish the air gap is the jack up or lift slab method.
The isolators can be either rubber or spring depending on the nature of the noise or vibration.
Housing suffix indicates housing height i e.
Vibration isolation technology has moved on to the isolation of entire buildings rather than just building components.
The mason fsn jack up acoustic floor system can be used as the crucial part of achieving box in box construction for studios or rooms requiring a high level of acoustic separation or simply providing acoustic or impact isolation from one area to another.
The fsn system ensures there is no bridging of the two elements due to slurry ingress plastic sheeting is placed on the sub floor as a breaker layer.
We have designed and manufactured neoprene and natural rubber bearing pads to frequencies as low as 6 hz and steel spring assemblies in the 0 75 to 2 00 inch 19 to 50mm deflection range in individual capacities of 1 000 000 lbs.
Our riverbank test data demonstrates that a four inch thick concrete floor floating on neoprene mounts improves the stc by 25 if raised two inches and that the inr goes up by 44.
A floor supported by mason low dynamic stiffness rubber the time tested low frequency exposure proof and truly structural material at lower cost.
Fsn4 indicates a 4 floor and housing.
Fsn6 a 6 floor and housing etc.
This uses the mason jack up system to raise a concrete layer.
Floating floors transitions and trim complement the flooring and provide a safe durable way to create expansion contraction space between areas and lead to other existing floors in the home.
Castings can be modified for floors over 6 thick.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concret.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concrete.
Plastic sheeting is placed on the sub floor as a breaker layer isolators are placed on the plastic sheeting reinforcing steel or mesh rests on the isolator housings and the concrete floor is poured.
Fsn rubber concrete jack up system.
Fsn 3 4 5 6 25 0 3500 12 47 12147 red white 50 60 1675 2350 3500 761 1068 1590 black gray fsn housing height matches floor thickness.